Tested to BS Standards
Up to 2 Hours Fire Rating.
Excellent Acoustic Insulation.
Suits wide range of walls and floors.
Suits wide range of pipe materials.
|
|
Insulated Fire Pipe Sleeve |
Product Description:
The acoustic insulated sleeves allow for thermal
movement of the pipe and maintain thermal insulation for the pipe through
the fire rated compartment penetration.
Suitable for the following configurations: Copper
12mm- 160mm, Mild steel 22mm - 160mm, Polybutylene 12mm - 28mm &
PVC 55mm-160mm.
The Insulated pipe sleeves have been tested with
a 27mm nominal wall thickness and have been tested cut both flush to
the wall / floor structure and leaving 25mm exposed for connection to
standard pipe insulation.
The insulated sleeves are quick & easy to install,
easy to cut and the sleeve may also be fitted flush to the wall for
a clean line solution.
Product Length 300mm.
Product Wall thickness 27mm.
Features:
Tested to BS Standards
Up to 2 Hours Fire Rating.
Excellent Acoustic Insulation.
Suitable a wide range of fire partition walls and floors.
Suitable for plastic, copper and mild steel pipes.
|

|
| Product
Test Matrix |
|
Pipe |
Blockwork
Wall |
Solid
Floor |
Mineral
Batt |
Plasterboard
Wall |
|
12MM Copper |
• |
• |
|
• |
|
160MM Copper |
• |
• |
|
• |
|
22MM Mild Steel |
• |
• |
|
• |
|
160MM Mild Steel |
• |
• |
|
• |
|
12MM Polybutylene |
• |
• |
• |
• |
|
28MM Polybutylene |
• |
• |
• |
• |
|
55MM PVC |
• |
• |
• |
• |
|
82MM PVC |
• |
• |
• |
• |
|
110MM PVC |
• |
• |
• |
• |
|
160MM PVC |
• |
• |
• |
• |
|
|
Other Information:
View Installation or Safety (COSHH) Datasheet on this page.
|
|
LEGAL:
As part of our policy of ongoing improvements, we reserve the right to
modify, alter or change product specifications without giving notice.
Product illustrations are representations only. All information contained
in this document is provided for guidance only, and as Intuchem Ltd has
no control over the installation methods of the products, or of the prevailing
site conditions, no warranties expressed or implied are intended to be
given as to the actual performance of the products mentioned or referred
to, and no liability whatsoever will be accepted for any loss, damage
or injury arising from the use of the information given of products mentioned
or referred to herein.
The above information to the best of our knowledge is true and accurate
and based upon current test data and is supplied for your guidance only.
Customers should satisfy themselves to the suitability of the product
in its intended use and no guarantee is given or implied since the conditions
of actual use are beyond our control. Intuchem Ltd disclaim any liability
for loss, damage or other expense arising from the use of information,
data or products mentioned or referred to and reserve the right to change
any details or specifications without notice.
|
|