Tested to EN & BS Standard
Up to 4 hours fire rating
4 size options
Removable for re-use
For wall & floor penetrations
Certifire Approval
|
|
Fire Pillows (intumescent) |
Product Description:
Intuchem Intumescent fire pillows will on reaction to
fire will expand and then harden to provide a durable and complete seal
to stop the spread of fire, smoke and hot gases. They are manufactured
from a tough specially treated glass cloth containing a mixt of mineral
fibres and reactive expansion agents.
Intumescent Fire Pillows can be used for creating either
temporary or permanent fire barriers and are ideal for sealing cable
trays and ducts that penetrate fire rated structures.
Intuchem intumescent fire pillows have Certifire approval
and are tested to EN & BS Standards and have up to a 4 Hour fire
rating.
Containing no asbestos or halogens so therefore can be specified for
use in areas such as exchanges, computer server rooms and in areas where
services are continually being modified.
Tested for Wall penetrations up to 600 x 600mm with a 4 hour rating
Tested for Floor penetrations up to 850 x 850mm with a 2 hour rating
Features:
Tested to EN & BS Standard
Up to 4 hours fire rating
4 size options
Removable for re-use
For wall & floor penetrations
Certifire Approval
|

|
| Dimensions: |
| Sizes |
|
|
| Large |
300mm x 200mm x 40mm |
ICPL |
| Medium |
300mm x 150mm x 40mm |
ICPM |
| Small |
300mm x 100mm x 40mm |
ICPS |
| Sausage |
300mm x 50mm x 40mm |
ICPSAS |
| |
|
|
|
|
Other Information:
View Installation or Safety (COSHH) Datasheet on this page.
|
|
LEGAL:
As part of our policy of ongoing improvements, we reserve the right to
modify, alter or change product specifications without giving notice.
Product illustrations are representations only. All information contained
in this document is provided for guidance only, and as Intuchem Ltd has
no control over the installation methods of the products, or of the prevailing
site conditions, no warranties expressed or implied are intended to be
given as to the actual performance of the products mentioned or referred
to, and no liability whatsoever will be accepted for any loss, damage
or injury arising from the use of the information given of products mentioned
or referred to herein.
The above information to the best of our knowledge is true and accurate
and based upon current test data and is supplied for your guidance only.
Customers should satisfy themselves to the suitability of the product
in its intended use and no guarantee is given or implied since the conditions
of actual use are beyond our control. Intuchem Ltd disclaim any liability
for loss, damage or other expense arising from the use of information,
data or products mentioned or referred to and reserve the right to change
any details or specifications without notice.
|
|