2 Hour Fire Rating
Acoustic Rated
Maintains Thermal insulation & Vapour Seal
Suitable for use through a wide range of
fire partition walls and floors
|
|
Ductwork Fire Stop |
Product Description:
Intuchem Ductwork Firestops are suitable for use where
a ventilation duct passes through a fire rated compartment wall. The
firestop will maintain the integrity of the fire rated compartment wall
which would otherwise be lost.
In the event of a fire, the duct work firestop will swell up and expand
with the heat, crushing the duct and closing off the route for the fire
for a period of 2 hours.
The Ventilation firestops are available to fit all common sizes of plastic
ventilation duct and are suitable for retro fitting with access only
required from one side. 25mm wall thickness
Features:
Tested to BS Standard
Suitable for fire partition walls & floors
Acoustic Rated
Maintains Thermal insulation & Vapour Seal
Suitable for use through a wide range of fire partition walls and floors
2 Hour Fire Rating
|

|
| Dimensions: |
|
Width [mm] |
Height [mm] |
Length [mm] |
Reference |
|
110 |
54 |
180 |
ICDWF110 |
|
150 |
70 |
180 |
ICDWF150 |
|
204 |
60 |
180 |
ICDWF204 |
|
215 |
25 |
180 |
ICDWF215 |
|
220 |
55 |
180 |
ICDWF220 |
|
225 |
25 |
180 |
ICDWF225 |
|
234 |
29 |
180 |
ICDWF235 |
|
300 |
25 |
180 |
ICDWF300 |
|
308 |
29 |
180 |
ICDWF308 |
|
50 |
50 |
150 |
ICDWF50 |
|
100 |
100 |
150 |
ICDWF100 |
|
|
|
Other Information:
View Installation or Safety (COSHH) Datasheet on this page.
|
|
LEGAL:
As part of our policy of ongoing improvements, we reserve the right to
modify, alter or change product specifications without giving notice.
Product illustrations are representations only. All information contained
in this document is provided for guidance only, and as Intuchem Ltd has
no control over the installation methods of the products, or of the prevailing
site conditions, no warranties expressed or implied are intended to be
given as to the actual performance of the products mentioned or referred
to, and no liability whatsoever will be accepted for any loss, damage
or injury arising from the use of the information given of products mentioned
or referred to herein.
The above information to the best of our knowledge is true and accurate
and based upon current test data and is supplied for your guidance only.
Customers should satisfy themselves to the suitability of the product
in its intended use and no guarantee is given or implied since the conditions
of actual use are beyond our control. Intuchem Ltd disclaim any liability
for loss, damage or other expense arising from the use of information,
data or products mentioned or referred to and reserve the right to change
any details or specifications without notice.
|
|